• 12Vdc to 24Vdc @ Idle: 40mA, Max: 100mA.
• 4 inputs and 2 outputs.
• Output 1 has an integrated relay. (Max 2 Amp @ 50V DC).
• Output 2 is an open collector output which can be connected directly
to the gate trigger (max 1 Amp @ 32V DC).
• Custom commands and buttons can be setup on the app to control the
outputs.
• Input 1 to 4 is triggered high by applying 12 or 24VDC to the input.
• Input trigger alert messages can be customized online.
• Energizer keypad data interface.
• Integrated E.T. NICE Cloud-Link receiver interface.
• Bluetooth enabled.
• Dimensions: 76 x 66 x 28mm
Get in Touch
Oce and Technical
+27 21 330 5016
Technical support
Whatsapp line:
+27 21 330 5016
Support hours:
Weekdays: 8:30-17:00
Saturday: 9:30-13:00
Sunday and Public holiday:
9:30-11:00
www.accentronix.co.za
• Two or more devices can eortlessly be linked together over the cloud to appear
as one device. This allows you to manage multiple devices connected to the
entrance, exit and pedestrian gates as one.
• A device can be linked to multiple accounts and dierent user levels can be
assigned by the owner.
• Use the output timers to automatically open the gate during peak-hours but keep
them closed during weekends and Public and School Holidays.
• Connect the entrance or exit loop through Output 1 to ensure a car must be at the
gate before allowing access.
• A missed-call on sim 1 will control output 1 as default, a dierent output can be
selected on the webportal to control.
• Output 1 and 2 delay timers can be used to activate a mag-lock or activate
entrance and exit loops for an allocated time.
• Set the integrated output timers to trigger the exit loop for 120 seconds to allow for
enough time for a visitor to reach the exit gate.
• Connect a Mag Lock directly to Output 1 (n/c) and (com)terminals of the
integrated relay and set the integrated output delay timer to 10 seconds.
• Connect Output 2 directly to the pedestrian trigger. Output 2 is an ‘open collector’
output which means it gives 0V to whatever it is connected to while it is switched
on. To drive heavier loads, connect the one end of the coil of an external (12/24V
DC coil) relay to 12/24V DC and the other end of the external relay’s coil to Output
2. If Output 2 is switched on, it will supply 0V to the relay and turn it on.
• Default SMS commands: On, O, Pulse, On2, O2, Pulse2, Status. These commands
will only work if your mobile number is loaded onto the access control list.
• NOTE: When connecting the Status and Alarm outputs of an ET Gate controller to
Input 1 and 2, you need to connect a 10K resistor between 12/24Vdc and Input 1
as well as a resistor between 12/24Vdc and Input 2.
• During power-up and after an update the GREEN LED will be solid for a few
seconds.
• The GREEN LED start flashing fast when the device registers on the GSM
network. After the device is successfully logged onto the cloud the LED will
flash slowly. This can take up to a minute.
• If the GREEN LED stay solid or keeps on flashing fast for more than 5minutes,
the sim cannot connect to the internet. Move the antenna to a higher
position and check the signal strength. Minimum recommended signal is 14.
Max is 31.
• Make sure the antenna is vertically mounted, not inside a metal enclosure or
close to any metal.
• To check the status, voltage and signal, sms 1234.status to sim one.
• The RED LED shows the on/o status of Output 2 as well as various error codes.
If connected to an energizer, a flashing RED LED indicates communication
with the keypad data connection.
• If you do not have the app installed on your phone, or if your phone lost its
internet connection, you will receive alerts by sms as a backup (max 30 sms’s
per month).
• Contact support on 021 330 5016 7 days a week for fast and friendly service
or go to our online HELP section for more info.
Trouble Shooting
Inputs, Outputs & Power Supply ABOUT THE SIM CARDS AND SUBSCRIPTIONS
One year premium subscription is included when you buy this device.
The following premium features is included:
• The included Vodacom or MTN sim cards have already been RICA registered
and activated with data by Accentronix.*
• The Accentronix Smart Home app, E.T. Remotes management, Tag management
and Google Home. Please note these functions are ONLY available while the
device is on subscription.
• All Data, 30 free backup SMS’s per month and unlimited updates.*
• Welcome sms containing instructions is sent to each new user.
• After 1 year, you will receive an invoice for renewal.
• Security upgrades and premium support is also included.
• Please see our Subscription Terms of Service for pricing.
• Please do not load any airitme or data on sims under subscription.
*Please see website for terms and
conditions and fair usage messaging
policy.
*Included sim cards and Free sms’ses
for South Africa only.
• Control your device by saying “Hey
Google, Is the garage closed?”,
“Turn the electric fence on” or “Turn
the sprinklers o”
• Simply download Google Home
from the app store and link
‘Accentronix Smart Home’ to your
account.
• This feature is available to anyone
who has their mobile numbers
added in the access control list.
• Go to the Google Home setup
section in the app for more info.
Download Our App
Accentronix Smart Home App
Using the App
• Control your gate and garage with a push of a
button.
• Use the app to invite a guest, learn a remote,
add a restricted access control user and
receive unlimited alerts and notifications.
• Devices and buttons will automatically appear
for any resident whose mobile number is linked
to the system. Residents will however not be
able to make any changes to the system or be
able to invite a guests if these features are not
enabled by admin.
App admin levels
• Dierent levels of admin privileges can be assigned depending on whether
you are the owner, access control administrator or a resident.
• Installers can use the app to set the device up, add and edit control buttons,
check status and test the device on site. Installers and admin need to link their
account in the ‘Admin Account’ section in the app to enable them to make
changes.
• As a backup service, you will receive alerts by normal SMS if your phone
temporarily lost its internet connection. You will also be able to control the
device by normal missed-call from within the app while you are oine.*
• All residents needs to download the Accentronix Smart Home App free of
charge.
Connection to Gate
ACCENTRONIX TAGS
HOW TO LEARN A TAG
1. Go to the ‘TAGS’ tab next to a user.
2. Click on ‘quick learn TAG’ and tap the
tag on the reader.
3. Press ‘Update device’ after adding
tags and users.
HOME AUTOMATION
Create custom buttons to control your lights, geyser, irrigation and
swimming pool pump. Monitor alarms, water tanks and even your
aquarium water level.
HOW TO CREATE CUSTOM BUTTONS ON THE APP
• Default buttons will automatically appear according to the
application type you selected when you registered the device.
• Customize names and commands of the buttons in the button
section.
• You can even set a button to control multiple outputs at the same
time i.e. “All lights o”.
• Expand the system by connecting an 8in/8out Expansion board.
HOW TO CONTROL YOUR ALARM PANEL
• Arm, disarm and monitor your alarm by connecting the device
directly to your alarm panel. See our online “How to” section for
connection diagrams and instruction on the most popular alarm
panels.
HOW TO SET THE DEVICE TO BE A STAND ALONE ALARM
SYSTEM
• Simply enable the “Alarm mode” option in the general setup
section. You will now be able to arm and disarm Input 1 to 3 of the
device for monitoring alarm and door sensors. Input 4 is used for a
panic button.
• Connect a siren to Output 1 and a status LED to Output 2.
• Arm and disarm by using the app, remote, tag reader or keypad.
• Remote buttons can be configured to arm/disarm, open a door
and panic.
ACCESS CONTROL
TIPS & FEATURES
Notes:
• You do not have to be on-site to learn a tag. Simply change
the ‘gateway’ option to the device you are the closest to. This
allows you to add tags to a site while you are on a dierent site.
Wireless Keypad
Google Home & Google
Assistant